Tel
+86-533-3880057
Email
info@sdjiajing.com

Biosafety Containment

Set A Consultation Today
Name can't be empty
Email error!
Message can't be empty
Send

*We respect your confidentiality and all information are protected.

Biosafety Containment
1
OUR ADVANTAGES
Why Choose Jiajing Medical
FAQS
FAQs of Endoscope Reprocessing
Choose the Best Biosafety Containment Systems Supplier

In laboratories, research facilities, and healthcare settings, biosafety containment systems are essential for protecting personnel, products, and the environment from hazardous biological agents. Key options include Clean Benches (Horizontal & Vertical) for product protection in non-hazardous work, Class II, Type A2 Biosafety Cabinets for balanced personnel/product/environmental protection with partial recirculation, and Class II, Type B2 Biosafety Cabinets for total exhaust in applications involving volatile chemicals or higher-risk pathogens. Selecting a reliable supplier ensures compliance with standards like NSF/ANSI 49, EN 12469, and CDC guidelines. In 2026, JIAJING Medical emerges as a top choice among Chinese manufacturers for these critical systems.

Understanding Biosafety Containment Options

Clean Bench (Horizontal & Vertical)

Clean benches, also known as laminar flow hoods, provide a sterile workspace by directing HEPA-filtered air over the work surface.

· Horizontal Flow: Air flows parallel to the work surface toward the operator—ideal for assembly or non-biohazard tasks.

· Vertical Flow: Downward airflow offers better operator protection while maintaining product sterility.

· Applications: Pharmaceutical compounding, electronics, or microbiology sample prep without hazardous agents.

· Limitations: No personnel protection against aerosols.

These are cost-effective for clean, non-pathogenic environments.

Class II, Type A2 Biosafety Cabinet

The most common biosafety cabinet (BSC), Type A2 recirculates 70% of air and exhausts 30% through HEPA filters.

· Key Features: Inflow velocity of at least 100 fpm; suitable for Biosafety Levels 1-3.

· Benefits: Protects operator, sample, and environment; can be ducted for volatiles in low concentrations.

· Applications: General microbiology, cell culture, and low-risk pathogen handling.

A2 cabinets are versatile and energy-efficient for most labs.

Class II, Type B2 Biosafety Cabinet

Type B2 features 100% total exhaust with no recirculation, making it ideal for work with volatile toxic chemicals or radionuclides alongside biological agents.

· Key Features: Higher inflow velocity; direct external ducting required.

· Benefits: Maximum personnel and environmental protection; no risk of buildup inside the cabinet.

· Applications: Oncology research, chemical microbiology, or high-containment needs.

Though more expensive to operate due to exhaust requirements, B2 is essential for hazardous volatile work.

Why Choose JIAJING Medical as Your Supplier

JIAJING Medical (Shandong Jiajing Medical Technology Co., Ltd.), established in 2016, specializes in infection control and biosafety solutions with over 15 years of R&D expertise. As a leading Chinese manufacturer, they offer a comprehensive range of containment systems tailored for modern laboratories.

· Product Excellence: Full lineup including Clean Benches (horizontal and vertical laminar flow), Class II Type A2 Biosafety Cabinets, and Class II Type B2 Biosafety Cabinets. Integrated with advanced HEPA/ULPA filtration, ergonomic designs, and smart controls.

· Certifications & Compliance: Products meet international standards (ISO, NSF/ANSI 49, EN), with rigorous testing for airflow, filter integrity, and safety.

· Innovation & Reliability: Backed by a dedicated R&D team focused on airborne infection control; seamless integration with other solutions like laminar flow canopies and air purifiers.

· One-Stop Service: From consultation and customization to installation and after-sales support, ensuring tailored solutions for labs, hospitals, and research institutions.

· Global Reach: Proven track record in exporting high-quality, cost-competitive equipment worldwide.

Compared to other suppliers, JIAJING Medical combines specialized expertise in biosafety containment with broader infection control portfolios, delivering value without compromising safety.

Key Factors in Selecting a Supplier

· Quality & Certifications: Verify third-party testing and compliance.

· Customization & Support: Ability to adapt sizes, features, and ducting.

· Cost vs. Performance: Balance initial investment with long-term reliability and energy efficiency.

· Reputation: Look for experience, customer feedback, and innovation.

In 2026, with rising demands for lab safety amid emerging pathogens, partnering with a trusted supplier like JIAJING Medical ensures your facility is equipped for the future. Consult their experts to assess your specific needs—whether a simple clean bench or advanced Class II B2 cabinet—and invest in containment systems that prioritize protection and performance.

 

 

Set A Consultation Today
Name can't be empty
Email error!
Message can't be empty
Send

*We respect your confidentiality and all information are protected.

Contact Us to Get Started
Jiajing medical is committed to medical equipment for airborne infection control, sterilization and endoscopy.
Contact Us Now
JIAJING MEDICAL
JIAJING MEDICAL
Contact Us Now
Name can't be empty
Email error!
Message can't be empty
code
error